Water: Meters and sensors

Water meters with pulse output and additional sensors to work with AMI system BALANCE.

Water meters with pulse output

Water meters with pulse output designed to pick up the amount of water passing through the meter and transmit signal to the radio module D100FC.

The sensors can be either built-in or removable. To be used in conjunction with the radio module D100FC will necessary cable connector CH325-03. When using a conventional cable that terminates the tip, will necessary to order an adapter screw too.

We recommend using meters with pulse transmitters of the company LLC “VALTEK”, LLC “Liom plus”, OAO “ГПЗ, which are designed to work with radio module D100FC and contain components to determine the short-circuit of the sensor, break sensor, as well as the impact of external magnetic field on the water meters.

 

Sensor with control

magnet field, break and

short- circuit

LLC “VALTEK”

water_1

Version

with pulse output

10 l / pulse

Water meter VLF-R-IL

LLC “VALTEK”

Russia St. Petersburg, 9 Line 4A of.5N

СУШИЦКИЙ Олег Иванович

+7 812 578-1320, +7 495 213-0373 ( Moscow)

e-mail: SushitskyOI@v-tg.com;

http://www.valtec.ru

Sensor with control

magnet field, break and

short- circuit

LLC “Liom plus”

water_2

Version

with pulse output

10 l / pulse

Water meter КВг 1,5i,  КВх 1,5i и КВУ 1,5i

LLCLiom plus

Russia St. Petersburg, 1st Upper Lane, 6

Павел Геннадьевич
t./f. +7 812 677-0349, 677-0350
e-mail: info@liomplus.ru;

www.liomplus.ru

Sensor with control

magnet field, break and

short- circuit

OAO “ГПЗ

water_3

Version

with pulse output

10 l / pulse

Water meter SSS(İSS)-15D; SSS(İSS)-20D

ОАО “ГПЗ,   Azerbaijan, Ganja, V.Huluflu, 1

Паша-заде Юсиф Гаджиевич

t/f +(994)22 550990,  m.t. +(994)50 2104451;

e-mail: abseron@mail.ru,

http://www.prompribor.azhttp://absheron-gcz.com

 

List of supported water meters contained in document DJV_Water_Heat_meters_ru.pdf. You can also use other water meters with pulse output “dry contact” with a maximum pulse frequency no less than 1 Hz and with pulse duration no less than 0.5 seconds.

 

Additional sensors to work in the AMI system BALANCE

For parameters control of the water supply can be used additional sensors: Pressure Switch – to control the pressure in the water supply system, the temperature sensor – to control the temperature of water and water leakage sensor to control flooding of the room and alarm emergency shutdown of the water supply network.

 

water_4  

Pressure Switch BLPS

– Setting dimension 8mm, G1/8″ Male

– Operating temperature from -30° C to + 80° C

– Pressure is open/closed    0.3/0.5 bar

– Cable – wire length 1.5m (2m)

– Class of Protection IP67, pressure up to 250 PSI

– Passport  BLPS-YKL02 200-0.3-0.5.jpg

water_5
  

Water leakage sensor LD-01

– It generates a signal when struck by water

– Safe voltage level – up to 3.6 volts

– Housing protected against splashing and wet floor

– Cable – wire length 1.5m (2m)

– In standby mode does not require power

– Built-break detection of sensor

water_6   

Temperature sensor DTI2-C, (B, A)

– Installation to a tee DN15 M

– Operating temperature range from +3° C to +100° C

– Temperature measurement accuracy C – 0,5° C; B – 0,12° C;  A – 0.06° C,

– Cable – wire length 1.5m (2m)

– Response time in the water not more than 12 s at 0.4 m/s

– Class of Protection IP67