{"id":249,"date":"2015-04-04T10:16:36","date_gmt":"2015-04-04T10:16:36","guid":{"rendered":"http:\/\/djv-com.org\/web00\/?p=249"},"modified":"2016-11-04T08:54:44","modified_gmt":"2016-11-04T08:54:44","slug":"d-mesh-communication-technology","status":"publish","type":"post","link":"http:\/\/djv-com.org\/web00\/?p=249","title":{"rendered":"D-Mesh communication technology"},"content":{"rendered":"<p class=\"c3 c15 c24\" style=\"text-align: center;\" class=\"lead\"><strong><span class=\"c22\">New generation wireless mesh networks<\/span><\/strong><\/p>\n<p class=\"c3 c15\"><strong><span class=\"c13\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a01. Characteristics of data networks.<\/span><span class=\"c5\">\u00a0<\/span><\/strong><\/p>\n<p class=\"c3 c15 c18\"><span class=\"c5\">Data transmission networks over the air, must meet the conflicting requirements depending on the application. To address specific problems you need to determine: the structure of the data transmission network, a way to access the channel data transmission, frequency range, data rate, battery life, the number of devices supported by the network, the amount of data transferred, response time network, the method of configuring the network, the coexistence of several networks simultaneously.<br \/>\nWe offer a stack of communication protocols D-Mesh and equipment for low-speed data networks. Operating frequency 315 MHz, 433MHz, 868MHz, 915MHz, 2,4 GHz does not require a license for their use.<br \/>\nSelf-organizing network is built on similar components. Ratio of active \/ passive mode is not more than 1 \/ 1000. The number of levels of relay 30. Power Device Battery. Battery 2A * h enough to work for 6 years. Frequency sharing between the devices configured and can be from 3 to 25 s. Response time the network is proportional to the number of levels of the network. Supports transfer autodata once a day, queries the current data, emergency messages. More transmitted information enables us to construct the structure of the data network.<\/span><\/p>\n<p class=\"c3\"><span class=\"c5\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/span><strong><span class=\"c13\">2. The structure of the data network.<\/span><\/strong><span class=\"c5\"><br \/>\nManufacturer DJV-COM has developed a network topology D-Mesh. This network topology supports all network devices. D-Mesh Topology is a kind of cluster tree topology (Figure 1). \u00a0<\/span><\/p>\n<p class=\"c3 c15\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image05.png\"><img loading=\"lazy\" decoding=\"async\" width=\"921\" height=\"503\" class=\"size-full wp-image-745 aligncenter\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image05.png\" alt=\"image05\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image05.png 921w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image05-300x164.png 300w\" sizes=\"auto, (max-width: 921px) 100vw, 921px\" \/><\/a><br \/>\n<span class=\"c25\"><br \/>\n<\/span><\/p>\n<p class=\"c3 c18\"><span class=\"c5\">D-Mesh topology allows most efficient use of bandwidth, combining data transfer rate sufficient for the transfer of daily data and the reliability of the network.<br \/>\nD-Mesh is a dynamic network topology, which routes the data can fluctuate, but the network node is installed permanently. When you add or delete network node will be automatically reconfiguring the network.<br \/>\nNetwork topology D-Mesh consists of a network coordinator and two types of network nodes with and off the routing function (Figure 2):<\/span><\/p>\n<p class=\"c3 c15\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image01.png\"><img loading=\"lazy\" decoding=\"async\" width=\"923\" height=\"397\" class=\"size-full wp-image-741 aligncenter\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image01.png\" alt=\"image01\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image01.png 923w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image01-300x129.png 300w\" sizes=\"auto, (max-width: 923px) 100vw, 923px\" \/><\/a><\/p>\n<p class=\"c3\"><span class=\"c5\">The coordinator of the network performs the concentrator. This device is the highest level of network topology. It can communicate with any devices in its network.<br \/>\nNetwork node with the enabled routing. This device, which acts as an intermediary between the network devices to transmit data from remote devices from the network coordinator. Network node can be as the final recipient of data.<br \/>\nNetwork node with the routing function is disabled. This is the final device in the network topology D-Mesh is the source or final destination of data, but with disabling routing.<br \/>\nEach device D-Mesh network has its own unique address.<\/span><\/p>\n<p class=\"c3\"><span class=\"c5\">\u00a0\u00a0\u00a0\u00a0<strong>\u00a0\u00a0\u00a0\u00a0\u00a0<\/strong><\/span><span class=\"c13\"><strong>3. The number of devices supported by the network.<\/strong> <\/span><span class=\"c5\"><br \/>\nAn important characteristic of data networks is the number of devices supported by the network. Since the network D-Mesh has a limit on the number of network nodes with routing enabled (no more than 240), a large number of devices to networks of regular or near-regular structure, it is recommended to use a topology \u00abBack Bone\u00bb (Fig. 3) .<\/span><\/p>\n<p class=\"c3 c15 c24\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image04.png\"><img loading=\"lazy\" decoding=\"async\" width=\"704\" height=\"544\" class=\"size-full wp-image-744 aligncenter\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image04.png\" alt=\"image04\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image04.png 704w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image04-300x232.png 300w\" sizes=\"auto, (max-width: 704px) 100vw, 704px\" \/><\/a><\/p>\n<p class=\"c3 c18\"><span class=\"c5\">If the apartment is based on several types of resources for one of the network devices of the apartment, such as a network node is installed on the gas meter is used enable routing, while for network devices installed in the apartment to accommodate other types of energy &#8211; water, heat , electricity, uses network nodes to disable the routing.<br \/>\nIf the house, it is usually not one riser, and a few, such as in Fig. 4<\/span><\/p>\n<p class=\"c3 c15 c24\"><span class=\"c5\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image06.png\"><img loading=\"lazy\" decoding=\"async\" width=\"706\" height=\"582\" class=\"size-full wp-image-746 aligncenter\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image06.png\" alt=\"image06\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image06.png 706w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image06-300x247.png 300w\" sizes=\"auto, (max-width: 706px) 100vw, 706px\" \/><\/a> <\/span><\/p>\n<p class=\"c3\"><span class=\"c5\">number of devices supported by one concentrator &#8211; can be increased by 4-6 times and brought to the numbers 1200 &#8211; 1500 points. If necessary, any network node with disable the routing, this feature can be activated remotely or locally.<\/span><\/p>\n<p class=\"c3\"><strong><span class=\"c13\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a04. Saving, or life of the battery.<\/span><\/strong><span class=\"c5\"><br \/>\nWe do not consider the network in which nodes in the network with routing functions require external ac\/dc power supply. In this case, lost many of the advantages of networks with data transmission on the radio &#8211; is the cost and time of deployment of such networks. To ensure the life of batteries for 6 -10 years old, requires that the device is active and not more than 1 \/ 1000 of the total operating time. For example, as shown in Fig. 5<\/span><\/p>\n<p class=\"c3 c15 c4\"><span class=\"c5\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image00.png\"><img loading=\"lazy\" decoding=\"async\" width=\"727\" height=\"400\" class=\"size-full wp-image-740 aligncenter\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image00.png\" alt=\"image00\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image00.png 727w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image00-300x165.png 300w\" sizes=\"auto, (max-width: 727px) 100vw, 727px\" \/><\/a> <\/span><\/p>\n<p class=\"c3\"><span class=\"c5\">data transmission subnet level is consistent, i.e. at the same time, in an active state is a very small number of devices.<\/span><\/p>\n<p class=\"c3\"><strong><span class=\"c5\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/span><span class=\"c13\">5. Load capacity bandwidth and reliability of the network.<\/span><\/strong><\/p>\n<p class=\"c3 c18\"><span class=\"c5\">An important parameter of the data network is the load capacity &#8211; the maximum possible number of data packets transmitted through a separate network node. So for D-Mesh network, each network node is able to pass a day at least 1500 data packets. Thus the data from the entire network &#8211; up to 1500 devices can be transferred to the coordinator through a single network node, which is the only link between the hub and the rest of the network.<br \/>\nAnother important parameter is the reliability of its network operations. Fig. 6 shows an example of the dynamic changes of network topology depending on the load of communication channels. The red color indicated the device in which the communication channel is overloaded transmission of data, in green &#8211; a device in which the communication channel is free. The example shows that with time the devices are idle channels to transmit their data. Thus, the network structure depends not only on the conditions of hearing devices over the air, but also on the busy channels. \u00a0<\/span><\/p>\n<p class=\"c3 c24\"><span class=\"c5\">\u00a0 <a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image03.png\"><img loading=\"lazy\" decoding=\"async\" width=\"673\" height=\"542\" class=\"alignleft size-full wp-image-743\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image03.png\" alt=\"image03\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image03.png 673w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image03-300x242.png 300w\" sizes=\"auto, (max-width: 673px) 100vw, 673px\" \/><\/a><\/span><\/p>\n<p class=\"c3\"><span class=\"c5\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/span><\/p>\n<p class=\"c3\"><strong><span class=\"c13\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a06. How to access the channel data.<\/span><span class=\"c5\">\u00a0<\/span><\/strong><\/p>\n<p class=\"c3\"><span class=\"c5\">To maximize \u00a0the operating \u00a0frequency range, \u00a0the network topology, D-Mesh used temporal separation of \u00a0data and timing (Figure 7).<br \/>\nWork \u00a0all \u00a0devices D-Mesh \u00a0network is \u00a0synchronized \u00a0with \u00a0the \u00a0beacon \u00a0signal \u00a0(beacon). \u00a0This signal is emitted periodically Networking sites-enabled routing, which may be the masters for some groups of devices. Signal beacon contains \u00a0information about the number of \u00a0network-level, \u00a0network ID, \u00a0the \u00a0MAC &#8211; the address of the master of his formative as well \u00a0as a number of additional data.<br \/>\nJust behind the beacon signal to be working window (Local Frame), the duration of which \u00a0consists \u00a0of two main parts. The first part \u00a0is \u00a0devoted \u00a0to \u00a0the transfer of data packets incoming messages, the second &#8211; outgoing. Length \u00a0of \u00a0the working window is variable.<\/span><\/p>\n<p class=\"c15 c28\"><span class=\"c25\">\u00a0 \u00a0 \u00a0 <a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image02.png\"><img loading=\"lazy\" decoding=\"async\" width=\"883\" height=\"346\" class=\"size-full wp-image-742 aligncenter\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image02.png\" alt=\"image02\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image02.png 883w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image02-300x118.png 300w\" sizes=\"auto, (max-width: 883px) 100vw, 883px\" \/><\/a><\/span><span class=\"c25\"><br \/>\n<\/span><\/p>\n<p class=\"c3\"><span class=\"c5\">In the pauses between the signals of the beacon, with the following working for them, windows, network devices are in sleep mode. If a device does not have time to make the transmission \/ reception of data during one working window, the whole process is divided into several working windows.<\/span><\/p>\n<p class=\"c3 c14\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image08.png\"><img loading=\"lazy\" decoding=\"async\" width=\"817\" height=\"640\" class=\"size-full wp-image-748 aligncenter\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image08.png\" alt=\"image08\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image08.png 817w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image08-300x235.png 300w\" sizes=\"auto, (max-width: 817px) 100vw, 817px\" \/><\/a><\/p>\n<p class=\"c3 c18\"><span class=\"c5\"><br \/>\nNetwork nodes can communicate with each other or with the coordinator of the network as the need arises in certain time intervals (Figure 8).<br \/>\nIn the topology of D-Mesh implemented two modes of operation of the network. In the presence of an external power supply network coordinator is constantly active and able to exchange data with the highest possible speed. As coordinator of the signals separate parts of the network periodically wake up and exchange messages.<br \/>\nIn the absence of external power supply network coordinator works in standalone mode and is powered by a battery backup unit. In this mode, the functioning of the entire network with the topology of D-Mesh is in sleep mode, including the coordinator. Data exchange occurs within the individual network segments, which are periodically wake up (Figure 5). Thus, it is possible not only to save electricity, but also to avoid the influence of individual network segments to each other.<\/span><\/p>\n<p class=\"c3\"><span class=\"c9\"><br \/>\n<\/span><strong><span class=\"c13\">7. Example topology of a running network.<\/span><span class=\"c5\">\u00a0<\/span><\/strong><\/p>\n<p class=\"c3\"><span class=\"c5\">As an example, the use of the D-Mesh give an example of a data collection system to integrate gas in high-rise building (Figure 9) at some point in time.<br \/>\nHours and daily data generated in the form of a data packet and sent to the control center once per day. In this time of radios without replacement lithium batteries last up to 6 years.<br \/>\nA distinctive feature of the radios company DJV-COM is the possibility of organizing a complex network architecture, as well as the opportunity to cover the distance, as measured by several kilometers through the maintenance of up to 30 levels of retransmission.<\/span><\/p>\n<p class=\"c3 c4\"><span class=\"c9\">\u00a0 \u00a0 \u00a0 \u00a0<\/span><\/p>\n<p class=\"c3 c4\"><span class=\"c9\">\u00a0 \u00a0 <a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image09.png\"><img loading=\"lazy\" decoding=\"async\" width=\"994\" height=\"820\" class=\"size-full wp-image-749 aligncenter\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image09.png\" alt=\"image09\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image09.png 994w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image09-300x247.png 300w\" sizes=\"auto, (max-width: 994px) 100vw, 994px\" \/><\/a><\/span><\/p>\n<p class=\"c3\"><span class=\"c5\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/span><strong><span class=\"c13\">8. Simultaneous operation of overlapping of hearing radio networks.<\/span><\/strong><span class=\"c5\"><br \/>\nWhen the mass installation of radio transmission raises the question of efficiency of networks with partial overlap of the hearing and a complete overlap (see Fig. 10).<\/span><\/p>\n<p class=\"c3 c20\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image07.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1058\" height=\"576\" class=\"size-full wp-image-747 aligncenter\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image07.png\" alt=\"image07\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image07.png 1058w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image07-300x163.png 300w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/04\/image07-1024x557.png 1024w\" sizes=\"auto, (max-width: 1058px) 100vw, 1058px\" \/><\/a><\/p>\n<p class=\"c3 c18\"><span class=\"c5\">Networks that are not provided the ability to work in conditions with partial or complete overlap of the hearing in the situation 1 will work normally, in situation 2 may frequent conflicts and the collapse of the network, in a situation 3 with complete overlap of the hearing &#8211; such a network will not work.<br \/>\nTechnology D-Mesh &#8211; allows you to configure the logical sign of the subnet zero to fifteen, so as to ensure proper performance for the situation 2 &#8211; to 16 subnets, and if the situation 3 &#8211; to 4 subnets with complete overlap. The number of collisions at the same time &#8211; is minimal.<\/span><\/p>\n<p class=\"c3\"><strong><span class=\"c9\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/span><\/strong><span class=\"c13\"><strong>9. Scope:<\/strong><br \/>\n<\/span><span class=\"c5\">The equipment used for network data collection and management. In particular, for the reading of the gas, water, electricity, heat metering, lighting control, water supply, gas, heat, ventilation and air conditioning control, transmission of alarms and build sensor networks that do not require constant data transfer, and transferring them to exit the parameter for a given range.<\/span><\/p>\n<p class=\"c3\"><span class=\"c9\">\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/span><\/p>\n<p class=\"c3 c15\"><span class=\"c13\">\u00a0\u00a0\u00a0\u00a0\u00a0<strong>\u00a0\u00a0\u00a010. Parameters of data network D-Mesh.<\/strong><br \/>\n<\/span><\/p>\n<table class=\"c31\" border=\"1\">\n<tbody>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Topology network<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Cluster tree<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">The number of devices supported by the network<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">To 1500 (of which 240 with the function of routing)<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">The volume of data transmitted on the network node \/ day<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">To 1500 packets<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Operating Frequency<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">433MHz (315, 868, 915, 2400 on request)<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Radiation power<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">&lt;10 mW<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c5 c16\">PHY<\/span><span class=\"c2\">\u00a0data rate<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">25 &#8211; 250 kBaud<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">The reliability of data<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">CRC16 + match data formats<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Immunity of data<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Frequency hopping<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Type of transmission \/ modulation<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Two-way communication \/ GFSK<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">The number of levels relay<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Up to 30<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Parameters of the input pulses<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">fmaks. &lt;= 1Hz, timp. &gt; = 500ms<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c8\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c3 c26\"><span class=\"c5\">Transmission range: \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Inside the buildings,<br \/>\n<\/span><span class=\"c5 c16\">Line-of-sight<\/span><\/p>\n<\/td>\n<td class=\"c21\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c3 c18\"><span class=\"c2\">\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a020 &#8211; 40 m<\/span><\/p>\n<p class=\"c3 c18\"><span class=\"c2\">\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 200 &#8211; 400 m<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Diameter of zone to be covered at an average distance of 70m<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">To 4200 meters<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Data with a timestamp<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Yes<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">High adaptability deployment \/ operation<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Yes<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">The need to configure the devices \/ network<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">No<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Additional installation \/ removal of individual devices<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Yes<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">The network working when changing external factors<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Yes<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Possibility of local RF access<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Yes<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">The efficiency due to overlapping networks of audibility<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Yes (up to 16 networks)<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Automatic routing<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Yes<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">The cost of a single point of network<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Minimal<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Dimensions radiomodul<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">68 x 55 x 32 mm<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Power supply \/ minimum life<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">lithium battery 2A * h \/ 6 years<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c8\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c3 c26\"><span class=\"c2\">Storing data in the absence of power<\/span><\/p>\n<\/td>\n<td class=\"c21\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c3 c26\"><span class=\"c2\">10 years<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c8\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c3 c26\"><span class=\"c2\">Data Buffer<\/span><\/p>\n<\/td>\n<td class=\"c21\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c3 c18\"><span class=\"c2\">60 days<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Degree of protection<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">IP51<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Operational temperature range radio module<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">from -20 to + 60 0C<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Warranty period<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">24 months<\/span><\/p>\n<\/td>\n<\/tr>\n<tr class=\"c0\">\n<td class=\"c1\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Compliance<\/span><\/p>\n<\/td>\n<td class=\"c11\" colspan=\"1\" rowspan=\"1\">\n<p class=\"c7\"><span class=\"c2\">Certificate of the Republic of Moldova<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>New generation wireless mesh networks \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a01. Characteristics of data networks.\u00a0 Data transmission networks over the air, must meet the conflicting requirements depending on the application. To address specific problems you need to determine: the structure of the data transmission network, a way to access the channel data transmission, frequency range, data rate, battery life, the&#8230;  <a href=\"http:\/\/djv-com.org\/web00\/?p=249\" class=\"more-link\" title=\"Read D-Mesh communication technology\">Read more &raquo;<\/a><\/p>\n","protected":false},"author":1,"featured_media":251,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[16],"tags":[],"class_list":["post-249","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology"],"_links":{"self":[{"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/posts\/249","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=249"}],"version-history":[{"count":3,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/posts\/249\/revisions"}],"predecessor-version":[{"id":750,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/posts\/249\/revisions\/750"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/media\/251"}],"wp:attachment":[{"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=249"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=249"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=249"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}