{"id":449,"date":"2015-09-16T12:30:40","date_gmt":"2015-09-16T12:30:40","guid":{"rendered":"http:\/\/djv-com.org\/web00\/?page_id=449"},"modified":"2015-10-26T12:31:31","modified_gmt":"2015-10-26T12:31:31","slug":"water-meters-and-sensors","status":"publish","type":"page","link":"http:\/\/djv-com.org\/web00\/?page_id=449","title":{"rendered":"Water: Meters and sensors"},"content":{"rendered":"<div class=\"poem_style\">\n<p class=\"lead\"><strong>Water meters with pulse output and additional sensors to work with AMI system BALANCE.<\/strong><\/p>\n<p><strong>Water meters with pulse output<\/strong><\/p>\n<p>Water meters with pulse output designed to pick up the amount of water passing through the meter and transmit signal to the radio module D100FC.<\/p>\n<p>The sensors can be either built-in or removable. To be used in conjunction with the radio module D100FC will necessary cable connector CH325-03. When using a conventional cable that terminates the tip, will necessary to order an adapter screw too.<\/p>\n<p>We recommend using meters with pulse transmitters of the company <strong>LLC &#8220;VALTEK&#8221;, LLC &#8220;Liom plus&#8221;, OAO &#8220;<\/strong><strong>\u0413\u041f\u0417<\/strong><strong>&#8220;<\/strong>, which are designed to work with radio module D100FC and contain components to determine the short-circuit of the sensor, break sensor, as well as the impact of external magnetic field on the water meters.<\/p>\n<p>&nbsp;<\/p>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td width=\"103\">\n<p style=\"text-align: center;\">Sensor with\u00a0control<\/p>\n<p style=\"text-align: center;\">magnet field,\u00a0break and<\/p>\n<p style=\"text-align: center;\">short- circuit<\/p>\n<p style=\"text-align: center;\"><span style=\"color: #3366ff;\"><strong>LLC &#8220;VALTEK&#8221;<\/strong><\/span><\/p>\n<\/td>\n<td width=\"120\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-481\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_1-150x150.jpg\" alt=\"water_1\" width=\"120\" height=\"124\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_1-291x300.jpg 291w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_1.jpg 300w\" sizes=\"auto, (max-width: 120px) 100vw, 120px\" \/><\/a><\/td>\n<td width=\"89\">\n<p style=\"text-align: center;\"><strong>Version <\/strong><\/p>\n<p style=\"text-align: center;\"><strong>with pulse output<\/strong><\/p>\n<p style=\"text-align: center;\"><strong>10 l \/ pulse<\/strong><\/p>\n<\/td>\n<td width=\"256\"><strong>Water meter <\/strong>VLF-R-IL<\/p>\n<p><span style=\"color: #3366ff;\"><strong>LLC &#8220;VALTEK&#8221;<\/strong><\/span><\/p>\n<p><strong>Russia<\/strong> St. Petersburg, 9 Line 4A of.5N<\/p>\n<p><strong>\u0421\u0423\u0428\u0418\u0426\u041a\u0418\u0419 \u041e\u043b\u0435\u0433 \u0418\u0432\u0430\u043d\u043e\u0432\u0438\u0447<\/strong><\/p>\n<p>+7\u00a0812 578-1320, +7 495 213-0373 ( Moscow)<\/p>\n<p>e-mail: <a href=\"mailto:SushitskyOI@v-tg.com\">SushitskyOI@v-tg.com<\/a>;<\/p>\n<p><a href=\"http:\/\/www.valtec.ru\/\">http:\/\/www.valtec.ru<\/a><\/td>\n<\/tr>\n<tr>\n<td width=\"103\">\n<p style=\"text-align: center;\">Sensor with\u00a0control<\/p>\n<p style=\"text-align: center;\">magnet field,\u00a0break and<\/p>\n<p style=\"text-align: center;\">short- circuit<\/p>\n<p style=\"text-align: center;\"><span style=\"color: #3366ff;\"><strong>LLC &#8220;Liom plus&#8221;<\/strong><\/span><\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"120\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-482\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_2-150x150.jpg\" alt=\"water_2\" width=\"120\" height=\"80\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_2-300x200.jpg 300w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_2.jpg 448w\" sizes=\"auto, (max-width: 120px) 100vw, 120px\" \/><\/a><\/td>\n<td width=\"89\">\n<p style=\"text-align: center;\"><strong>Version <\/strong><\/p>\n<p style=\"text-align: center;\"><strong>with pulse output<\/strong><\/p>\n<p style=\"text-align: center;\"><strong>10 l \/ pulse<\/strong><\/p>\n<\/td>\n<td width=\"256\"><strong>Water meter <\/strong><strong>\u041a\u0412\u0433<\/strong><strong> 1,5i<\/strong><strong>, \u00a0<\/strong><strong>\u041a\u0412\u0445<\/strong><strong> 1,5i <\/strong><strong>\u0438<\/strong> <strong>\u041a\u0412\u0423<\/strong><strong> 1,5i<\/strong><\/p>\n<p><span style=\"color: #3366ff;\"><strong>LLC<\/strong><strong> &#8220;<\/strong><strong>Liom<\/strong> <strong>plus<\/strong><strong>&#8220;<\/strong><\/span><\/p>\n<p><strong>Russia<\/strong> St. Petersburg, 1st Upper Lane, 6<\/p>\n<p><strong>\u041f\u0430\u0432\u0435\u043b \u0413\u0435\u043d\u043d\u0430\u0434\u044c\u0435\u0432\u0438\u0447<\/strong><br \/>\nt.\/f. +7 812 677-0349, 677-0350<br \/>\ne-mail: <u><a href=\"..\/AppData\/Local\/Temp\/bat\/sentmsg?compose&amp;To=info@liomplus.ru\">info@liomplus.ru<\/a>;<\/u><\/p>\n<p><u><a href=\"http:\/\/www.liomplus.ru\">www.liomplus.ru<\/a><\/u><\/td>\n<\/tr>\n<tr>\n<td width=\"103\">\n<p style=\"text-align: center;\">Sensor with\u00a0control<\/p>\n<p style=\"text-align: center;\">magnet field,\u00a0break and<\/p>\n<p style=\"text-align: center;\">short- circuit<\/p>\n<p style=\"text-align: center;\"><span style=\"color: #3366ff;\"><strong>OAO &#8220;<\/strong><strong>\u0413\u041f\u0417<\/strong><strong>&#8220;<\/strong><\/span><\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"120\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-483\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_3-150x150.jpg\" alt=\"water_3\" width=\"120\" height=\"120\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_3-150x150.jpg 150w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_3-300x300.jpg 300w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_3-125x125.jpg 125w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_3.jpg 671w\" sizes=\"auto, (max-width: 120px) 100vw, 120px\" \/><\/a><\/td>\n<td width=\"89\">\n<p style=\"text-align: center;\"><strong>Version <\/strong><\/p>\n<p style=\"text-align: center;\"><strong>with pulse output<\/strong><\/p>\n<p style=\"text-align: center;\"><strong>10 l \/ pulse<\/strong><\/p>\n<\/td>\n<td width=\"256\"><strong>Water meter <em><a href=\"http:\/\/nasos.kg\/vodomer_absheron_kv\/328-sss304ss-15d-sss304ss-20d.html\">SSS(\u0130SS)-15D; SSS(\u0130SS)-20D<\/a><\/em><\/strong><\/p>\n<p><span style=\"color: #3366ff;\"><strong>\u041e\u0410\u041e<\/strong><strong> &#8220;\u0413\u041f\u0417<\/strong><\/span><strong><span style=\"color: #3366ff;\">&#8220;<\/span>,<\/strong><strong> \u00a0<\/strong>\u00a0<strong>Azerbaijan, <\/strong>Ganja, V.Huluflu, 1<\/p>\n<p><strong>\u041f\u0430\u0448\u0430-\u0437\u0430\u0434\u0435 \u042e\u0441\u0438\u0444 \u0413\u0430\u0434\u0436\u0438\u0435\u0432\u0438\u0447<\/strong><\/p>\n<p>t\/f +(994)22 550990, \u00a0m.t. +(994)50 2104451;<\/p>\n<p>e-mail: <a href=\"mailto:abseron@mail.ru\">abseron<\/a><a href=\"mailto:abseron@mail.ru\">@<\/a><a href=\"mailto:abseron@mail.ru\">mail<\/a><a href=\"mailto:abseron@mail.ru\">.<\/a><a href=\"mailto:abseron@mail.ru\">ru<\/a>,<\/p>\n<p><a href=\"http:\/\/www.prompribor.az\/\">http<\/a><a href=\"http:\/\/www.prompribor.az\/\">:\/\/<\/a><a href=\"http:\/\/www.prompribor.az\/\">www<\/a><a href=\"http:\/\/www.prompribor.az\/\">.<\/a><a href=\"http:\/\/www.prompribor.az\/\">prompribor<\/a><a href=\"http:\/\/www.prompribor.az\/\">.<\/a><a href=\"http:\/\/www.prompribor.az\/\">az<\/a>,\u00a0 <a href=\"http:\/\/absheron-gcz.com\">http:\/\/absheron-gcz.com<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>List of supported water meters contained in document <strong><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/DJV_Water_Heat_meters_ru.pdf\" target=\"_blank\">DJV_Water_Heat_meters_ru.pdf<\/a><\/strong>. You can also use other water meters with pulse output &#8220;dry contact&#8221; with a maximum pulse frequency no less than 1 Hz and with pulse duration no less than 0.5 seconds.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Additional sensors to work in the AMI system BALANCE<\/strong><\/p>\n<p>For parameters control of the water supply can be used additional sensors: Pressure Switch &#8211; to control the pressure in the water supply system, the temperature sensor &#8211; to control the temperature of water and water leakage sensor to control flooding of the room and alarm emergency shutdown of the water supply network.<\/p>\n<p>&nbsp;<\/p>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td width=\"130\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_4.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-484\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_4-150x150.png\" alt=\"water_4\" width=\"130\" height=\"88\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_4-300x202.png 300w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_4.png 392w\" sizes=\"auto, (max-width: 130px) 100vw, 130px\" \/><\/a><\/td>\n<td width=\"448\"><strong>\u00a0 <\/strong><\/p>\n<p><strong>Pressure Switch<\/strong> <strong>BLPS <\/strong><\/p>\n<p>&#8211; Setting dimension 8mm, G1\/8&#8243; Male<\/p>\n<p>&#8211; Operating temperature from -30\u00b0 C to + 80\u00b0 C<\/p>\n<p>&#8211; Pressure is open\/closed \u00a0\u00a0\u00a00.3\/0.5 bar<\/p>\n<p>&#8211; Cable &#8211; wire length 1.5m (2m)<\/p>\n<p>&#8211; Class of Protection IP67, pressure up to 250 PSI<\/p>\n<p>&#8211; Passport \u00a0<u><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/BLPS-YKL02-200-0.3-0.5.jpg\" target=\"_blank\">BLPS-YKL02 200-0.3-0.5.jpg<\/a><\/u><\/td>\n<\/tr>\n<tr>\n<td width=\"130\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_5.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-485\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_5-150x150.jpg\" alt=\"water_5\" width=\"130\" height=\"131\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_5-150x150.jpg 150w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_5-125x125.jpg 125w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_5.jpg 250w\" sizes=\"auto, (max-width: 130px) 100vw, 130px\" \/><\/a><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_3.jpg\"><br \/>\n<\/a><\/td>\n<td width=\"448\"><strong>\u00a0\u00a0 <\/strong><\/p>\n<p><strong>Water leakage sensor LD-01<\/strong><\/p>\n<p>&#8211; It generates a signal when struck by water<\/p>\n<p>&#8211; Safe voltage level &#8211; up to 3.6 volts<\/p>\n<p>&#8211; Housing protected against splashing and wet floor<\/p>\n<p>&#8211; Cable &#8211; wire length 1.5m (2m)<\/p>\n<p>&#8211; In standby mode does not require power<\/p>\n<p>&#8211; Built-break detection of sensor<\/td>\n<\/tr>\n<tr>\n<td width=\"130\"><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_6.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-486\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_6-150x150.jpg\" alt=\"water_6\" width=\"130\" height=\"98\" srcset=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_6-300x225.jpg 300w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_6-1024x768.jpg 1024w, http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/09\/water_6.jpg 1632w\" sizes=\"auto, (max-width: 130px) 100vw, 130px\" \/><\/a><\/td>\n<td width=\"448\"><strong>\u00a0\u00a0 <\/strong><\/p>\n<p><strong>Temperature sensor DTI2-C, (B, A)<\/strong><\/p>\n<p>&#8211; Installation to a tee DN15 M<\/p>\n<p>&#8211; Operating temperature range from +3\u00b0 C to +100\u00b0 C<\/p>\n<p>&#8211; Temperature measurement accuracy C &#8211; 0,5\u00b0 C; B &#8211; 0,12\u00b0 C; \u00a0A &#8211; 0.06\u00b0 C,<\/p>\n<p>&#8211; Cable &#8211; wire length 1.5m (2m)<\/p>\n<p>&#8211; Response time in the water not more than 12 s at 0.4 m\/s<\/p>\n<p>&#8211; Class of Protection IP67<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Water meters with pulse output and additional sensors to work with AMI system BALANCE. Water meters with pulse output Water meters with pulse output designed to pick up the amount of water passing through the meter and transmit signal to the radio module D100FC. The sensors can be either built-in or removable. To be used&#8230;  <a href=\"http:\/\/djv-com.org\/web00\/?page_id=449\" class=\"more-link\" title=\"Read Water: Meters and sensors\">Read more &raquo;<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":23,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-449","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/pages\/449","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=449"}],"version-history":[{"count":13,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/pages\/449\/revisions"}],"predecessor-version":[{"id":505,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/pages\/449\/revisions\/505"}],"up":[{"embeddable":true,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/pages\/23"}],"wp:attachment":[{"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=449"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}