{"id":162,"date":"2015-03-01T15:21:22","date_gmt":"2015-03-01T15:21:22","guid":{"rendered":"http:\/\/djv-com.org\/web00\/?page_id=162"},"modified":"2015-10-13T11:29:45","modified_gmt":"2015-10-13T11:29:45","slug":"gas-composition-of-the-system-for-the-user","status":"publish","type":"page","link":"http:\/\/djv-com.org\/web00\/?page_id=162","title":{"rendered":"Gas: Composition of the system for the user"},"content":{"rendered":"<div class=\"poem_style\">\n<p class=\"lead\"><strong>The organization of gas data collection.<\/strong><\/p>\n<p>Gas (water) \u00a0metering \u00a0in \u00a0an apartment of the consumer is carried out by means of the meter with a pulse output. The meter is equipped with the radio module with dry contact.<\/p>\n<p>As \u00a0the \u00a0communication \u00a0environment \u00a0indoors \u00a0using \u00a0\u00a0local \u00a0radio \u00a0network. \u00a0Further, in the area \u00a0from the house to the data collection center as the physical medium for communication using GSM\/GPRS.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Application<\/strong><\/p>\n<p>Meters can communicate directly with the concentrator. \u00a0\u00a0However if conditions of audibility appear worse admissible, radio modules carry out functions of repetition.<\/p>\n<p>&nbsp;<\/p>\n<a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/03\/123.gif\"><img loading=\"lazy\" decoding=\"async\" width=\"626\" height=\"185\" class=\"aligncenter size-full wp-image-349\" src=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/03\/123.gif\" alt=\"123\" \/><\/a>\n<p>&nbsp;<\/p>\n<p><strong>Some variants of data transmission in the Center are possible:<\/strong><\/p>\n<p>* GSM &#8211; the \u00a0concentrator \u00a0is \u00a0completed \u00a0with the \u00a0GSM \u00a0modem \u00a0and \u00a0data \u00a0are \u00a0passed \u00a0to \u00a0the \u00a0Center.<\/p>\n<p>* Data \u00a0\u00a0\u00a0\u00a0transmission \u00a0\u00a0\u00a0\u00a0periodically \u00a0\u00a0\u00a0\u00a0from\u00a0\u00a0\u00a0 \u00a0\u00a0concentrator \u00a0\u00a0\u00a0to \u00a0\u00a0notebook \u00a0\u00a0through \u00a0\u00a0\u00a0USB\u00a0\u00a0 \u00a0interface.<\/p>\n<p>* Data transmission one times in a month from the radio module to terminal of manual data \u00a0gathering on the radio-channel (Walk-By, Drive-By). \u00a0\u00a0By \u00a0this \u00a0principle \u00a0it \u00a0is \u00a0possible to get data \u00a0from radio modules established at the separate consumers. Direct access to meter unit is not required.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>The advantages<\/strong><strong> of solutions based on radio:<\/strong><\/p>\n<p>* Automatic meter reading radio increases the speed of data collection from meters<\/p>\n<p>* The\u00a0 reliability\u00a0 of\u00a0 the\u00a0 data\u00a0 is\u00a0 greatly\u00a0 improved\u00a0 due\u00a0 to\u00a0 the elimination\u00a0 errors\u00a0 in \u00a0data\u00a0 recording \u00a0or transmission.<\/p>\n<p>* Reading of the radio also opens access to all the counters, even in cases where the consumer is not in place or if the meter is in a remote place.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Technology<\/strong><strong>\u00a0<\/strong><\/p>\n<p>* Frequency range 433MHz does not require a license.<\/p>\n<p>* Thanks\u00a0 to\u00a0 the\u00a0 new\u00a0 technology\u00a0 module &#8220;D100-F&#8221; also works reliably in harsh environments and in the presence of interference<\/p>\n<p>* D100-F\u00a0 provides\u00a0 accounting,\u00a0 recording\u00a0 in\u00a0 memory\u00a0 and\u00a0 the\u00a0 transmission\u00a0 of\u00a0 impulses consumption<\/p>\n<p>* Every day radio transmits consumption data to the concentrator.<\/p>\n<p>* The radio allows the issuance of additional data:\u00a0 time stamps and events of radio modules and sensors<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Ease of<\/strong><strong> deployment<\/strong><\/p>\n<p>* No cost for the design.<\/p>\n<p>* No cost for laying communication cables.<\/p>\n<p>* The radio modules and pulse the sensors is easily installed on the gas meters.<\/p>\n<p>* Does not require any work on the setting up and configuring the system &#8211; all done automatically.<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>Advanced Features<\/strong><\/p>\n<p>* Daily readings for accurate billing, even in cases where the owner of the apartment was replaced<\/p>\n<p>* Leak detection by analyzing the hourly charts of consumption, creating additional savings for energy consumers<\/p>\n<p>* Transfer the alarm if necessary, for regular battery replacement<\/p>\n<p>* Sending alarm when unauthorized access to the pulse sensor<\/p>\n<p>* The system may be used to accommodate different kinds of energy by connecting to the electricity meters, water or heat.<\/p>\n<p>&nbsp;<\/p>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td colspan=\"2\" width=\"626\">\u00a0<strong>Technical <\/strong><strong>Characteristics<\/strong><strong>:<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0Frequency range<\/td>\n<td width=\"298\">\u00a0433MHz<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0Radiation power<\/td>\n<td width=\"298\">\u00a0&lt; 10 mW<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0Kind of transfer data \/ Modulation<\/td>\n<td width=\"298\">\u00a0Bidirectional communication \/ GFSK<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0Number of repetition levels<\/td>\n<td width=\"298\">\u00a0Up to 30<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0Characteristics of an external pulse<\/td>\n<td width=\"298\">\u00a0f max\u00a0&lt;= 1Hz, t pulse. &gt;= 500ms<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0Range of transfer:<\/p>\n<p>Inside of buildings,<\/p>\n<p>On the open district<\/td>\n<td width=\"298\">&nbsp;<\/p>\n<p>20 &#8211;\u00a0\u00a040 \u043c<\/p>\n<p>200 &#8211; 400 \u043c<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0Dimensions<\/td>\n<td width=\"298\">\u00a068 \u0445 55 \u0445 32 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0The power supply \/ the Minimal service life<\/td>\n<td width=\"298\">\u00a0lithium battery\u00a0 2 \u2013 4 A*h\/ 6 &#8211; 8 years<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0Data storage in absence of a power<\/td>\n<td width=\"298\">\u00a010 years<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0The size of the buffer of data<\/td>\n<td width=\"298\">\u00a096 hours\/ 4 days<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0Degree of protection of the case<\/td>\n<td width=\"298\">\u00a0IP51<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0Range of working temperatures<\/td>\n<td width=\"298\">\u00a0from -20 \u00a0to + 60 \u2018\u0421 (-40 \u00a0to + 85 \u2018\u0421)<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0Warranty period<\/td>\n<td width=\"298\">\u00a024 month<\/td>\n<\/tr>\n<tr>\n<td width=\"327\">\u00a0Conformity to standards<\/td>\n<td width=\"298\">\u00a0The certificate of Republic Moldova and Ukrain<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/djv-com.org\/web00\/wp-content\/uploads\/2015\/03\/djv_gas_en.pdf\" target=\"_blank\"><strong>Gas Metering Presentation (pdf)<\/strong><\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The organization of gas data collection. Gas (water) \u00a0metering \u00a0in \u00a0an apartment of the consumer is carried out by means of the meter with a pulse output. The meter is equipped with the radio module with dry contact. As \u00a0the \u00a0communication \u00a0environment \u00a0indoors \u00a0using \u00a0\u00a0local \u00a0radio \u00a0network. \u00a0Further, in the area \u00a0from the house to&#8230;  <a href=\"http:\/\/djv-com.org\/web00\/?page_id=162\" class=\"more-link\" title=\"Read Gas: Composition of the system for the user\">Read more &raquo;<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":20,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-162","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/pages\/162","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=162"}],"version-history":[{"count":5,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/pages\/162\/revisions"}],"predecessor-version":[{"id":507,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/pages\/162\/revisions\/507"}],"up":[{"embeddable":true,"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=\/wp\/v2\/pages\/20"}],"wp:attachment":[{"href":"http:\/\/djv-com.org\/web00\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=162"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}